Capacitor Switching Contactor

Capacitor Switching Contactor

Details
The CJ19C Capacitor Switching Contactor represents a purpose-built solution for the safe and efficient switching of low-voltage shunt capacitors. As a dedicated component, it is widely employed in automatic compensation-based reactive power compensation setups. This product is engineered for AC systems with a frequency of 50Hz and a rated working voltage up to 380V, proficiently making and breaking capacitive loads up to 90kvar to enhance overall power factor.
Category
Low-Voltage Apparatus
Share to
Send Inquiry
Description
Technical Parameters

The CJ19C Capacitor Switching Contactor represents a purpose-built solution for the safe and efficient switching of low-voltage shunt capacitors. As a dedicated component, it is widely employed in automatic compensation-based reactive power compensation setups. This product is engineered for AC systems with a frequency of 50Hz and a rated working voltage up to 380V, proficiently making and breaking capacitive loads up to 90kvar to enhance overall power factor. Its design philosophy centers on a modular "building-block" approach. Notably, the resistor circuit, configured in three paths, is situated above the main power circuit section. The main contacts are intelligently designed for reliable, solo load operation. For guaranteed performance, the Capacitor Switching Contactor must be applied under these specified conditions: a) The surrounding air temperature should be between -5°C and +40°C, with the 24-hour average temperature not exceeding +35°C. b) The installation site's altitude is limited to 2000m above sea level. c) Air relative humidity at the installation point should not exceed 50% when the temperature is +40°C. Additionally, the average minimum temperature of the wettest month is ≤+25°C, and that month's average maximum relative humidity is ≤90%. d) A pollution degree of 3 is applicable. e) It falls under installation category III. f) The installation location must be free from pronounced shaking, impact, or vibration. g)

The contactor should be mounted such that its surface does not incline more than 5° from vertical. The core functionality of this product is illustrated in Figure 1. The diagram above the dashed line details the capacitor switching circuitry, while the section below shows the parallel capacitor bank. The resistor switching circuit, comprising early-make contacts in series with resistors, activates first when the electromagnetic coil is powered. Current initially charges the capacitors through these resistors, effectively restraining the switch-on surge current. Subsequently, the main contacts close to carry the full capacitor current. This intelligent sequence ensures smooth engagement. Furthermore, once the inrush suppression task is complete, the resistor circuit within the Capacitor Switching Contactor automatically disengages from the main circuit and resets. This action substantially reduces the opportunity for resistors to overheat or burn out during the capacitor cutoff process, offering superior protection and extended service life for critical compensation system assets.

product-411-617

Internal Connections and Terminal Markings

 

See Figure 2 for the circuit connections and terminal markings of the CJ19C type.

The resistor of the CJ19C-63 contactor is connected to a dedicated terminal on the main wiring terminal,to avoid interference from external wiring during main wiring terminal operation.

The CJ19C-63 contactor has three auxiliary contacts, with two combinations; auxiliary contact combinations are shown in Table 1. Auxiliary modules can be installed on both sides of the contactor to increase the number of auxiliary contacts.

product-1074-747
Two types of auxiliary modules are available:

LA8-DN11 (one normally open and one normally closed)

LA8-DN20 (two normally open); selected by the user when ordering.

Contactor Model

Auxiliary Contact

Normally Open (NO)

Normally Closed (NC)

CJ19C-63

21E

2

1

12E

1

2

Controlled capacitor 400V

Capacity Qn kvar

32kvar

Rated current InA

46A

Operating current 1.3 In A

60A

Conventional heating current IthA

69A

Suppression of inrush capacity

20 In

Coil

Operating voltage 50Hz Us V

220,380 According to user needs

Range of motion

0.85~1.1Us

Power consumption VA

Start

200

Absorption

20

Short circuit protection fuse rated current selection

1.5~2.5In

Rated insulation voltage UiV

690V

Auxiliary contact for heating current AC 15 A

10A

Mechanical life

800000 times
Electrical life operating frequency120 1/h 80000 times
weight about1.25kg

 

External Shape and Installation Dimensions:

The CJ19C-63 contactor can be installed using M6 screws and lock washers, or using 35mm or 75mm mounting rails.

See Figure 4 for the external shape and installation dimensions of the CJ19C-63.

product-929-784

Qualification

product-794-1123
product-794-1123
product-794-1123
product-794-1123
product-794-1123
product-794-1123
product-794-1123
product-794-1123
product-794-1123
product-794-1123
product-794-1123
product-794-1123
product-794-1123
product-793-1125
 

 

Hot Tags: capacitor switching contactor, China capacitor switching contactor factory, Reactive Power Compensation Control Cabinet Contactor, Programmable Contactor, Low Voltage Capacitor Contactor, Contactor for Capacitor Bank, AC Contactor Accessories, Capacitive Contactor with Damping Resistor

Send Inquiry
Contact usif have any question

You can either contact us via phone, email or online form below. Our specialist will contact you back shortly.

Contact now!