Reactive Power Compensation Cabinet Components

Reactive Power Compensation Cabinet Components

Details
As integral product, the CJ19C single-phase series contactors are specialized devices designed for switching low-voltage single-phase capacitors or for providing split-phase compensation in three-phase systems. These essential Reactive Power Compensation Cabinet Components are deployed within automatic compensation equipment dedicated to power factor correction.
Category
Low-Voltage Apparatus
 
Send Inquiry
Description
Technical Parameters

As integral product, the CJ19C single-phase series contactors are specialized devices designed for switching low-voltage single-phase capacitors or for providing split-phase compensation in three-phase systems. These essential Reactive Power Compensation Cabinet Components are deployed within automatic compensation equipment dedicated to power factor correction. They are suitable for AC power systems with a frequency of 50Hz and a rated working voltage up to 220V, capably making and breaking connections to capacitive loads as high as 90kvar to ensure efficient power factor improvement. This single-phase capacitor switching contactor is an improved design manufactured by our plant, evolving from the original CJ19C (16C) platform to offer enhanced reliability as a cabinet component.

For seamless and reliable operation as part of a compensation cabinet assembly, these product must be applied under the following specified conditions: a) Ambient air temperature: the upper limit is +40°C, the 24-hour average value must not exceed +35°C, and the lower limit is -5°C. b) Altitude: the cabinet installation site should not be higher than 2000m. c) Humidity: at the installation location, the air relative humidity should not exceed 50% when the temperature is +40°C. The average minimum temperature of the wettest month does not exceed +25°C, and that month's average maximum relative humidity does not exceed 90%. d) Pollution degree: 3. e) Installation category: III. f) Shock and vibration: These Reactive Power Compensation Cabinet Components must be installed within the cabinet in a location free from significant shaking, impact, or vibration. g) Installation condition: The inclination of the component's mounting surface relative to the vertical plane should not exceed 5°. Their working principle, illustrated in Figure 1, is key to cabinet performance. The schematic above the dotted line shows the control circuit; below is the single-phase capacitor bank. The integrated resistor switching circuit (early-make contacts with series resistors) closes first upon coil energization, limiting inrush current during capacitor charging. Subsequently, the main contacts close to carry the load. A vital feature of these Reactive Power Compensation Cabinet Components is the automatic disconnection and reset of the resistor circuit post-suppression, significantly reducing the risk of resistor burnout and ensuring the cabinet's long-term, maintenance-friendly operation.

product-439-704

Internal Connections and Terminal Markings

 

CJ19C Single-Phase and Three-Phase Y-Type (requires three contactors) Wiring diagram is shown in Figure 2.

The CJ19C (Single-Phase)-115~170 contactor has one auxiliary contact, available in two combinations.

Auxiliary contact combinations are shown in Table 1. Auxiliary modules can be installed on both sides of the contactor to increase the number of auxiliary contacts.

product-1039-765
Two types of auxiliary modules are available:

LA8-DN11 (one normally open and one normally closed)

LA8-DN20 (two normally open); selected by the user when ordering.

Contactor Model

Auxiliary Contact

Normally Open (NO)

Normally Closed (NC)

CJ19C(Single phase)-115

10E

1

-

01E

-

1

Controlled capacitor 400V

Capacity Qn kvar

60kvar

Rated current InA

260A

Operating current 1.3 In A

339A

Conventional heating current IthA

750A

Suppression of inrush capacity

20 In

Coil

Operating voltage 50Hz Us V

220,380 According to user needs

Range of motion

0.85~1.1Us

Power consumption VA

Start

300

Absorption

22

Short circuit protection fuse rated current selection

1.5~2.5In

Rated insulation voltage UiV

1140V

Auxiliary contact designation for heating current AC 15 A

10A

Mechanical life

200000times
Electrical life operating frequency120 1/h 20000times
Weight About 2.3kg

 

External Dimensions and Installation Dimensions:

The CJ19C (single-phase)-1150 contactor can be installed using M6 screws and lock washers, or using two 35mm mounting rails with a center distance of 105mm between the rails. The external dimensions and installation dimensions of the CJ19C (single-phase)-115 contactor are shown in Figure 5.

product-944-755

Qualification

product-794-1123
product-794-1123
product-794-1123
product-794-1123
product-794-1123
product-794-1123
product-794-1123
product-794-1123
product-794-1123
product-794-1123
product-794-1123
product-794-1123
product-794-1123
product-793-1125
 

 

Hot Tags: reactive power compensation cabinet components, China reactive power compensation cabinet components factory, Reactive Power Compensation Control Cabinet Contactor, Programmable Contactor, Low Voltage Capacitor Contactor, Contactor for Capacitor Bank, AC Contactor Accessories, Capacitive Contactor with Damping Resistor

Send Inquiry
Contact usif have any question

You can either contact us via phone, email or online form below. Our specialist will contact you back shortly.

Contact now!