Product Description
Dynamic reactive compensation unit is designed for low-voltage power distribution systems that require fast phase-separated capacitor switching and stable reactive power compensation under unbalanced load conditions. This TSC series reactive power compensation switching regulator is an electronic power device used for rapid switching of parallel capacitors in AC 50/60Hz distribution systems with rated working voltage of 400V or 230V. The main circuit adopts anti-parallel thyristor modules, while the triggering circuit, synchronization circuit, and control circuit work together to complete fast and accurate switching operation. The control circuit and control signal use photoelectric isolation, helping reduce mutual interference during operation. When the compensation controller sends a switching command, the thyristor conducts or cuts off quickly, allowing the corresponding capacitor bank to be connected or disconnected without the mechanical impact, contact wear, sparks, and operating noise commonly associated with traditional electromagnetic contactors.
Our factory develops this dynamic reactive compensation unit for compensation cabinet manufacturers, electrical panel builders, industrial power distribution projects, and overseas distributors who need a higher-capacity split compensation switching solution. In many industrial and commercial power systems, three-phase loads are often unbalanced. Production lines, welding equipment, elevators, motors, compressors, pumps, HVAC systems, and mixed commercial loads may create different reactive power demands on A, B, and C phases. This TSC-0.23-20-Y model is suitable for split compensation applications, using capacitors with a three-phase Y connection and rated voltage of 0.23KV. The control signal is divided into three channels, allowing each phase to be switched separately according to the actual compensation requirement. With a maximum controlled capacitor capacity of 20×3Kvar and a recommended fast fuse rated current of 125A, this dynamic reactive compensation unit is suitable for customers who need stronger phase compensation capability, faster switching response, and more stable cabinet operation. For agents and project buyers, it can be supplied as an individual switching unit or combined with capacitors, controllers, contactors, and other reactive power compensation components to build a more complete low-voltage compensation solution.
Specifications
| Product Type | TSC Series Reactive Power Compensation Switching Regulator |
| Model Reference | TSC-0.23-20-Y |
| Application System | Low-voltage dynamic reactive power compensation device |
| Rated Voltage | 400V / 230V |
| Rated Frequency | 50/60Hz |
| Control Capacity | 400V common compensation: 10Kvar-70Kvar; 230V split compensation: 3Kvar-20Kvar |
| Compensation Type | Split compensation |
| Capacitor Connection | Three-phase Y connection |
| Controlled Phase | A/B/C phase-separated switching |
| Maximum Controlled Capacitor Capacity | 20×3Kvar |
| Control Terminal Voltage | DC12V |
| Control Terminal Current | 5mA |
| Discharge Circuit | Built-in discharge circuit, discharge time less than 10 seconds, peak value 50V |
| Switching Method | Anti-parallel thyristor module fast switching |
| Main Features | No inrush current, no overvoltage, no sparks, low operating noise, frequent switching, overheat protection |
| Ambient Temperature | -5℃ to +40℃, average temperature within 24h not higher than +35℃ |
| Altitude | Not more than 2000m |
| Main Terminal Wiring Capacity | Maximum 25mm² insulated wire, terminal lugs recommended |
| Recommended Protection Device | NGT or NTOO fast fuse |
| Recommended Fuse Rated Current for TSC-0.23-20-Y | 125A |
| Applicable Installation Size Range | Common compensation above 50Kvar, split compensation above 17Kvar |
| Installation Dimensions | A/B/C/F/H*/G/D/E = 145/240/200/120/145/167/35/218mm |
| Installation Method | Mounted on the compensation device installation plate or frame rail |
| Installation Note | Reserve ventilation space around the heat sink and temperature-controlled fan area |
Applications
Split reactive power compensation cabinets
Used inside low-voltage split compensation cabinets where A, B, and C phases need independent capacitor switching according to actual reactive power demand.
Three-phase unbalanced load systems
Suitable for electrical systems where load distribution is uneven across phases, helping the compensation system respond more accurately than common three-phase switching.
Industrial production and equipment rooms
Applied in factories, workshops, compressor stations, pump rooms, welding areas, motor control systems, and production lines with frequent load fluctuation.
Commercial and public building power systems
Used in office buildings, shopping centers, hotels, hospitals, and public facilities where phase load changes may occur throughout daily operation.
Electrical panel and project integration
Designed for panel builders, compensation cabinet manufacturers, and electrical contractors who need a thyristor-based dynamic reactive compensation unit for 230V split compensation systems.
Factory Strength
Our factory has been engaged in electrical product manufacturing since the early 1990s, with long-term focus on capacitor switching contactors and reactive power compensation components. We operate a production facility of more than 3,000 square meters, have our own R&D team, and maintain a monthly production capacity of about 5,000 units. For overseas customers purchasing dynamic reactive compensation unit products, this manufacturing base supports stable supply, repeat orders, project replacement demand, and long-term cooperation.
Our product range includes capacitor switching contactors, AC contactors, self-healing low-voltage parallel power capacitors, dynamic reactive power compensation switching regulators, ultra-fast dynamic reactive power compensation switching regulators, intelligent capacitor composite switches, automatic reactive power compensation controllers, and harmonic filters. This allows customers to source related compensation cabinet components from one manufacturer. For distributors, a more complete product range makes it easier to build a professional local catalog; for project buyers, it helps reduce model matching problems and improves communication efficiency during cabinet design and procurement.
Customization Capability
We support OEM/ODM service for customers who need branded supply or project-based product adjustment. Customization can be discussed according to actual order requirements, including casing color, logo, control voltage, product label, and cabinet matching requirements. If customers provide technical drawings or prototypes, our factory can evaluate production feasibility and confirm the required development process. For customized products, R&D cost and development time depend on the actual structure, electrical requirements, testing needs, and application scenario.
Samples can be provided before mass production for technical verification. This is especially useful for distributors introducing a dynamic reactive compensation unit into a new market, or for panel builders testing compatibility with local controllers, capacitor banks, wiring layouts, and protection devices. Mixed specifications can also be discussed according to order requirements, helping agents prepare stock for different cabinet capacities and project configurations.
Quality Control
Our factory has ISO9001 quality management system certification and CCC National Compulsory Product Certification. During production, we apply regular inspection methods and carry out 100% inspection before packing. Third-party inspection is accepted when required by customers or engineering projects. For this dynamic reactive compensation unit, quality control focuses on thyristor module assembly, control signal response, A/B/C phase switching reliability, terminal connection condition, insulation safety, thermal protection, product labeling, and packing condition.
Because this model is designed for split compensation and higher phase capacity, correct installation and protection selection are especially important. The product instruction recommends using semiconductor fast fuses such as NGT or NTOO type, and the TSC-0.23-20-Y model uses a recommended fuse rated current of 125A. The main terminal can connect up to 25mm² insulated wire, and terminal lugs are recommended for reliable wiring. During cabinet installation, enough ventilation space should be reserved around the heat sink and temperature-controlled fan area. These details help cabinet manufacturers improve commissioning efficiency, reduce wiring risk, and support stable long-term operation of the complete compensation system.

FAQ
Q1: What is the main function of this dynamic reactive compensation unit?
A1: It is used for fast switching of parallel capacitors in low-voltage dynamic reactive power compensation systems. The TSC-0.23-20-Y model is suitable for split compensation applications where A, B, and C phases need separate switching control.
Q2: What capacitor capacity can the TSC-0.23-20-Y model control?
A2: The TSC-0.23-20-Y model is designed for 20×3Kvar capacitor control, and the recommended fast fuse rated current is 125A.
Q3: What type of capacitor connection does this model use?
A3: This model is used with capacitors in a three-phase Y connection. It supports phase-separated switching, making it suitable for systems with unbalanced three-phase loads.
Q4: Can this product replace traditional electromagnetic contactors?
A4: Yes. It is a suitable alternative for dynamic compensation systems where frequent switching, low noise, no sparks, reduced inrush current, and reduced overvoltage are required.
Q5: Can samples or OEM/ODM service be provided?
A5: Yes. Samples can be provided before mass production, and OEM/ODM service is supported. Custom production can be evaluated according to drawings, prototypes, labeling requirements, control voltage requirements, and actual project application needs.
Hot Tags: dynamic reactive compensation unit, China dynamic reactive compensation unit factory